WUXI GLOBAL POWER TECHNOLOGY CO.,LTD
User First, Honesty Based; Create GP-brand by Quality, Gain reputation by Service.
Product Details:
Payment & Shipping Terms:
|
| Rated Power: | 800kw 1000kva | Engine Bramd: | Perkins |
|---|---|---|---|
| Frequency: | 50/60 Hz | Speed: | 1500 Rpm |
| Rated Voltage: | 400V/380V/230V | Out Put: | AC Three Phase |
| Color: | Blue (Optional) | Coolong System: | Water-cooled |
| Highlight: | brushless alternator generator,engine generator set |
||
800kw Prekins water cooled diesel generator 1000kva super perkins generator
Technical Specifications :
Genset:
| Prime Power (kw/kva) | 800/1000 |
| Standby Power (kw/kva) | 880/1100 |
| Rated Voltage (V) | 400/230 |
| Voltage Recovery Time | ≤1S |
| Rated Current (A) | 1440 |
| Rated Frequency (Hz) | 50 |
| Frequency Recovery Time | ≤5S |
| Wave Distortion | ≤5%, sine wave |
| Running Noise db(A)/7m(Silent type) | 75 |
| Battery capacity (V-Ah) | 24V 100Ah |
| Open Type-Dimension (L*W*H) (mm) | 4450*1650*2403 |
| Open Type-Weight (kg) | 7750 |
| Soundproof Type- Dimension (L*W*H) (mm) | 20ft container |
| Soundproof Type-Weight (kg) | 19350 |
| Fuel Tank Capacity(L) | 1200 |
| Continuous Running Time(hr.) | 6 |
Engine:
| Engine brand | Perkins |
| Output Power (kw) | 899 |
| Cylinder No. & Config. | 8, in-line |
| Combustion System | direct injection |
| Compression Ratio | 13.6:1 |
| Displacement (L) | 30.561 |
| Bore X Stroke (mm) | 160*190 |
| Engine Speed (r/min) | 1500 |
| Speed Governing | Electronic |
| Starting System | 24V DC Electric |
| Filter System | Dry oil filter/Fuel filter/Oil filter |
| Cooling system | Water-cooled |
| Coolant capacity (L) | 143(Temp.) / 149(Trop.) |
| Fuel Consump. (g/kw·h) | 206 |
Alternator:
| Alternator brand | Stamford |
| Rated Power (kw) | 648 |
| Excitation System | Brushless, self-exciting |
| Voltage Regulation Mode | AVR |
| Connection Type | 3phase,4wires,”Y” connection |
| Pole No. | 4 |
| Rotation Speed (r/min) | 1500 |
| Temperature Rise (℃) | 125 |
| Insulation class | H |
| Voltage Regulation (0 load) | ≥95%~105% |
| Voltage accuracy | ≤±1% |
| Protection Grade | IP23 |
| Telephone Influence Factor | TIF<50 |
| Harmonic Coefficient | THF<2% |
Control System:![]()
1, Manual control system, the basic type control system is provided with a current meter, a volmeter, a frequency meter, an oil pressure guage, a water thermometer and indicator lights on the control cabinet and 4 additional protection fuctions are to be provided as required by customers.
2, AST (Automatic Start Type Control System), Optional Automatic Start Type System is provided When there is an interruption in the commercial power supply (or there is a start signal in other generator sets), this generator set will, subject to time delay acknowledgement (0-30 S adjustable), be automatically started (1-8 times
adjustable). In addition, it is provided with a basic protection function and digital or meter indication of voltage,
current, frequency and rotation speed parameters.
3, ATS (Automatic Transfer System), The optional system is provided with a fully automatic transfer switch, a control electric apparatus and an indicator light on the control panel and is coordinated with an automatic type contral cabinet, thus serving the fuction of automatic changeover between the power supplied by the grid and the power generated by the genset.
4, Sync Parallel Control System, this control system can connect 2 or 3 or 4 gensets to make more larger power.
such as: if you want 1000kw power, you can choose 2 sets 500kw gensets to work together, using this control system can make 1000kw power.
Our Picture :![]()
![]()
Basic Specification:
Our advantages :
1.Inspection
1. Each engine shall be tested at manufacturer’s workshop to certify the engine output according to present standard and fuel consumption in accordance with the site operating condition specified by purchaser on the specification datasheet.
2. All relevant information drawings pertinent to the testing and test procedure shall be transmitted to the purchaser in advance of the test date notification.
3. All accompanied documents are corresponding to the actual situation of generators, including the Qualified Certificate, Parameters and the Performance Index.
2.Guarantee
1) Guarantee Period: One year or 1000 running hours whichever comes first.
2) During the guarantee period, the spare-parts will be sent through your shipping agency in China.
3) Spare-parts can also be sent by air express.
4) 24 hours service hotline is available for customers.
Our Service :
1. If you are interested in our products we sincerely invite you to take a visit of our factory when you are in China. We can drive to pick you up and visit our factory.
2. Suggest the best choice or referential suggestion based on customers’ information. Answer all questions about the product from customer.
3. Build customers’ profiles, follow-up service, make regular calls on customers.